8-channel Valve Control System
Perfusion is critical in most biological applications, both for maintaining the viability of
preparations and establishing experimental conditions. Electronic control of solution exchange
improves fluid delivery and enhances reproducibility over manual methods. With the BPS-8
systems, you can configure systems for the basic requirements of the student lab or you can
optimize them for the most demanding applications of patch-clamp recording and / or imaging.
- Highly configurable to users requirements
- Easy to assemble and setup
- Manual and TTL control of valves
- Low electrical noise
- gravity or pressure driven systems
- variety of reservoir sizes
- Option of pinch valve or ALA's Lee Co. valve*.
* New redesigned Lee Co. mini valve exclusively for ALA.
8-channel Valve Control System
Perfusion is critical in most biological applications, both for maintaining the viability of
preparations and establishing experimental conditions. Electronic control of solution exchange
improves fluid delivery and enhances reproducibility over manual methods. With the BPS-8
systems, you can configure systems for the basic requirements of the student lab or you can
optimize them for the most demanding applications of patch-clamp recording and / or imaging.
The BPS-8 are modular systems that allow for fast and easy setup. All systems are designed to minimize electronic noise, therefore it is suited for electrophyiological recordings. You can control your valve openings from the BPS-8C valve controller, manually, or from your data acquisition software using the convenient TTL inputs on the controller housing. Gravity-driven systems are affordable and easily adjusted by positioning the reservoir manifold; more expensive pressure driven systems make precise adjustment
of flow rates even easier.
ALA has two valve options: three-way pinch valves or soleniod valves made exclusively for ALA by the Lee Co. The pinch valves allow selection of default-open or default-closed positions to reduce heat dissipation to solutions. The
pinch tubing is cleaned by rinsing the tubing; because there are no internally wettable surfaces, maintenance consists of periodically exchanging pinch tubing. ALA's solenoid valves are optimized for high-speed solution exchange. These valves feature a biologically inert internally wettable surface and give valve opening times of less than two msec. All ALA systems can be configured with 5, 10 or 60 ml reservoirs. As with all ALA instruments, custom configurations are also available.
All gravity systems consist of a magnetic stand that hold the valve and the reservoir manifolds, an electronic valve controller, tubing, and a standard Minimanifold™ outlet. The standard reservoirs are 60ml luer lock syringes and include 3 way stop cock luer valves. The entire reservoir assembly as well as individual reservoirs can be moved up/down in order to balance fluid flow. The fluid is directed into the standard 4 to 1 inlet (MMF-8, Minimanifold™) and then flows out a single output tube. Options include different reservoirs sizes and other 4 to 1 perfusion outlets (MLF-8, Millimanifold™).
All pressure systems (BPS-8SP shown) consist of a magnetic stand that hold the valve and pressure reservoirs manifolds,
an electronic controller, and tubing. Each pressurized system comes standard with the Minimanifold™outlet in case the user wants to switch to gravity for a particular study. Other outlets can be via an optional Millimanifold™ for large area focal perfusion. For the ultimate in fast focal drug application the system can be used with ALA’s Micromanifold® (QMM-8 ). Pinch or soleniod valves are availabvle. To pressurize the system, the optional PR-10, Pressure Regulator is suggested.
All
downloads are in pdf format. Use Acrobat Reader to view. If you do not have
the latest Reader, download it from the Adobe webpage for free
To save a pdf file to your local machine, right mouse click on link and choose
"Save Target As...". You then choose the destination folder you
want to save the pdf file to.
manual
| prospectus
All BPS systems can be configured with the following options:
| Valves |
| ALA L2V |
Custom built Lee Co. 12V solenoid valves |
| ALA PV |
12V 3-way Pinch valves |
| Reservoirs |
| ALA 5mlRES |
5ml reservoir with pressure plug , 3-way stop cock and tubing. |
| ALA 10mlRES |
10ml reservoir with pressure plug, 3-way stop cock and tubing. |
| ALA 60mlRES |
60ml reservoir with pressure plug, 3-way stop cock and tubing. |
| ALA 60mlSYR |
60ml syringe with luer |
| Compression Fittings |
| ALA CF-1 |
1/16" id tubing to 0.024"(0.61mm) od micro tubing reducer for focal solution applicators |
| ALA CF-2 |
1/16" id tubing to 0.03"(0.76mm) od micro tubing reducer for focal solution applicators |
| |
|
| Perfusion manifolds |
| ALA QMM-4/WT |
4 to1 quartz capillary front end. ID sizes available from 100 to 500 micron. |
| ALA MLF-4 |
4 to 1 polyamide 500 µm id front end |
| ALA MMF-4 |
4 to 1 ABS 1/16" id front end |
| Accessories |
| ALA PR-10 |
10 psi dual pressure regulator |