NPI CellWorks
Let us help you...
- build a perfusion system.
Last update
July 29, 2004
© copyright 2003
ALA Scientific Instruments
Acquisition Software
The Turnkey Software Solution for Experimental Control and Data Acquisition
CellWorks (npi electronic) is a modular program especially developed for executing complex
electro-physiological and pharmacological investigations and other laboratory
experiments on living cells under computer control. The software package not
only performs data recordings, but is designed for complete control of the
entire experimental setup allowing the automated execution of experimental
procedures.
Acquisition Software
The Turnkey Software Solution for Experimental Control and Data Acquisition
CellWorks (npi electronic) is a modular program especially developed for executing complex
electro-physiological and pharmacological investigations and other laboratory
experiments on living cells under computer control. The software package not
only performs data recordings, but is designed for complete control of the
entire experimental setup allowing the automated execution of experimental
procedures.
Outstanding features include
- Powerful solution and drug application management, handles lists of solutions
- Operated through an icon based, graphical, user friendly platform with multi
user capability
- Available for PCs with WINDOWS 95 / 98, Windows NT 4.0 / 2000 / XP
- Can be used on notebooks with PCMCIA interface cards from National Instruments
- Powerful editors and configuration routines make the design of turnkey solutions
for different experimental situations easy
- Applications include stimulation, perfusion, pump control, presetting and
direct control of the recording amplifier, communication with optical recording
devices, data acquisition and storage to hard disk
- Data can be exported directly to IGOR Pro.
- Multi-functional interface boards from National Instruments, serial ports,
the INT-10 and INT-20 breakout boxes and the VD-24 universal valve controller
from npi provide the link to your experimental setup
- Can be adapted to a virtually infinite number of users and experimental
environments
- CellWorks E: 16 analog input channels (12 bit or 16 bit, up to 50 kHz /
channel, range ±10 V) OUTPUTS: 2 analog output channels (12 bit or 16 bit),
up to 96 TTL lines, (with additional DIO boards), 8 power outputs (5 V - 24
V / 0.5 A) with breakout box for perfusion valve control.
CellWorks 5.5 Demo version is fully functional, but has no hardware interface
and is not protected by a dongle. The hardware is simulated within CellWorks
Demo. This allows not only a realistic look into the program, but also evaluation
of data recorded with CellWorks full version.
Download
CellWorks 5.5 Demo 7.5 MB.
Available for PCs with WINDOWS 95 / 98, Windows NT 4.0 / 2000 / XP
National Instrument cards recommended:
PCI-6024E
Multifunction I/O, 12-bit, National Instruments
16 analog inputs (single ended), 2 analog outputs, 8 digital I/O lines, maximum
Sampling rate 200 kS/s, maximum input range ±10 V, see also Data Acquisition
Hardware
PCI-6036E
Multifunction I/O, 16-bit, National Instruments
16 analog inputs (single ended), 2 analog outputs, 8 digital I/O lines, maximum
Sampling rate 200 kS/s, maximum input range ±10 V, see also Data Acquisition
Hardware
All
downloads are in pdf format. Use Acrobat Reader to view. If you do not have
the latest Reader, download it from the Adobe webpage for free
To save a pdf file to your local machine, right mouse click on link and choose
"Save Target As...". You then choose the destination folder you
want to save the pdf file to.
manual
| prospectus
| references
CWL-X
CellWorks software
PCI-6024E
Multifunction I/O, 12-bit, National Instruments
16 analog inputs (single ended), 2 analog outputs, 8 digital I/O lines, maximum
Sampling rate 200 kS/s, maximum input range ±10 V, see also Data Acquisition
Hardware
PCI-6036E
Multifunction I/O, 16-bit, National Instruments
16 analog inputs (single ended), 2 analog outputs, 8 digital I/O lines, maximum
Sampling rate 200 kS/s, maximum input range ±10 V, see also Data Acquisition
Hardware
INT-20X
Breakout box
For data acquisition boards of the EE series from National Instruments, e.g.
PCI-6024E or PCI-6036E
CW-VM-4PG
4 channel system
Pinch valves, gravity fed, 60 ml reservoires
CW-VM-4PP
4 channel system
Pinch valves, pressurized, 5 mlreservoires, needs pressure controller (e.g.
PR-10)
CW-VM-4SG
4 channel system
Lee solenoid valves, gravity fed, 60 ml reservoires
CW-VM-4SP
4 channel system with Lee valves
Lee solenoid valves, pressurized, 5 ml reservoires, needs pressure controller
(e.g. PR-10)
CW-VM-8PG
8 channel system
Pinch valves, gravity fed, 60 ml reservoires
CW-VM-8PP
8 channel system
Pinch valves, pressurized, 5 ml reservoires, needs pressure controller (e.g.
PR-10)
CW-VM-8SG
8 channel system
Lee solenoid valves, gravity fed, 60 ml reservoires
CW-VM-8SP
8 channel system
Lee solenoid valves, pressurized, 5 ml reservoires, needs pressure controller
(e.g. PR-10)
PR-10
Pressure controller
0-0.7 bar (0-10 psi)